Electrical Safety & Energization Lead
- Field, BC, Canada
Full-time
Applications open in a new tab.
Job details
- Job type
- Full-time
- Apply by
- Posting language
- English
- Posted
Original job description
- Nationwide (Field-Heavy)
- ZA-35011
- Nationwide (Field-Heavy)
- Field-Heavy
- Compensation discussed during final conversation
Every commissioning scope on energized MV switchgear requires someone who manages the safety boundary - the person who establishes approach limits, verifies PPE, coordinates LOTO, and controls the energization sequence. This role exists because energization safety on medium-voltage switchgear with concurrent energized and de-energized zones cannot be an afterthought delegated to the lowest-available person. You own the safety plan for every commissioning phase. When boards are being cut over while adjacent boards serve live loads, you define the approach boundaries, manage the energization sequence, and verify compliance before power is applied.
What You Own
- Energization procedures and safety plans for multi-source MV critical power facilities
- LOTO procedures and verification for concurrent energized/de-energized zones on adjacent switchboard sections
- Approach boundary management (limited, restricted, prohibited) per NFPA 70E 130.4(E)
- Arc-flash PPE category assignments based on IEEE 1584 incident energy calculations across all operating modes
- Daily safety briefings, qualified electrical worker rosters, and safety documentation for each commissioning phase
- Pre-energization safety walkdowns - verifying all safety boundaries, PPE, and isolation points before power is applied
- Coordination with site stakeholders: Operations, Safety, Mission Assurance (or owner equivalent)
Standards
NFPA 70E NFPA 70 (NEC) NFPA 110/111 (EPSS) IEEE 1584
Vendor Platforms
SEL Woodward
Test Phases
Factory Acceptance Test (FAT) Site Acceptance Test (SAT) Witness testing Staged commissioning / cutover
What Success Looks Like
First 90 Days
- Managed energization safety on at least one active commissioning project - safety plans, LOTO, approach boundaries
- Produced a per-phase energization procedure with safety boundary diagrams accepted by project leadership
- Conducted daily safety briefings and pre-energization walkdowns for a commissioning crew
- Owning energization safety across concurrent commissioning projects - setting safety standards and procedures
- PPE category assignments verified against current arc-flash study results for all operating configurations
- Recognized by commissioning crews and prime contractor teams as the safety authority for P&C commissioning
- 10+ years in electrical safety, commissioning, or field engineering on medium-voltage power systems
- NFPA 70E expert-level knowledge: approach boundaries, PPE categories, energized work permits, LOTO management
- Arc-flash study interpretation per IEEE 1584 - incident energy, PPE assignments, approach boundary calculations
- Experience managing concurrent energized and de-energized zones during staged commissioning
- Energization procedure development for multi-source critical power (generators, ATS, UPS, switchgear)
- Safety plan coordination with site operations, safety personnel, and owner representatives
- NETA Level IV certification
- OSHA 30 or equivalent electrical safety certification
- Experience at federal facilities, data centers, or mission-critical infrastructure with formal safety protocols
- International commissioning experience (different local regulations alongside NFPA 70E)
- Arc-flash study development per IEEE 1584 (not just interpretation)
Travel 60–80% during commissioning campaigns. Nationwide deployment with advance scheduling.
Site Hours Off-hours energization windows (nights, weekends) when required by site operations. Presence required at every energization event.
Customer-Facing Direct coordination with site safety, operations, and owner representatives. You are the safety authority during commissioning.
Documentation Heavy - energization procedures, safety plans, LOTO documentation, approach boundary diagrams, qualified worker rosters, daily briefing records
Field Safety You define the safety program. Arc-flash PPE (Cat 2–4 for MV), LOTO management, approach boundary establishment, safety briefing leadership.
Why Ziggurat
- Your safety judgment is the final gate before energization - the highest-consequence decision on any commissioning project
- Small firm means your safety standards define the practice, not a corporate safety department you report into
- Work on the most complex commissioning scenarios: concurrent zones, live-site cutovers, multi-source MV
- Direct access to the principal engineer who designed the protection system you are energizing
1
Screen
Background review against role requirements - vendor platform experience, relevant certifications, project types, and standards familiarity. Quick assessment of baseline alignment before investing either party's time.
Resume review + 15-min intro call
2
Technical Review
Deeper evaluation of technical depth. We review sample work - relay settings files, protection study reports, commissioning test procedures, or SCADA configuration packages - depending on the role. If samples aren't shareable, we discuss specific project scenarios in detail.
Async work-sample review or 45-min technical call
3
Interview
Scenario-based conversation with the principal engineer. Real project situations: how you'd approach a coordination study for a complex switchgear lineup, sequence a commissioning plan across multiple vendor platforms, or troubleshoot a protection scheme failure during site acceptance testing.
60-min video call with founder
4
Exercise / Artifact Review
A practical evaluation matched to the role. Engineering roles receive a take-home exercise - review and mark up a set of relay settings, identify gaps in a protection study, or develop a test procedure for a specific scheme. Field-focused roles walk through a commissioning package or test report they've delivered, explaining their methodology and decisions.
Take-home exercise (2–4 hrs) or artifact walkthrough (60 min)
5
Final Conversation
Role scope, current project pipeline, working arrangements, and compensation. This is a two-way conversation - we want to confirm the role fits your goals, not just the other way around.
30-min call
This role supports our Testing & Commissioning service scopes.
Questions about this role? Email us at careers@zigguratautomation.com
Not ready to apply?
Stay on our radar - we'll reach out when a role matches your background.
General interest Protection & Relay EngineeringPower System Studies & DesignCommissioning & Field ExecutionIntegration & ControlsProject & Deployment Management
Get in Early
This role opens soon.
Send your background now - we'll call you when it opens.
Express Interest See All Roles
More about this job
Responsibilities
Lead electrical safety for medium-voltage commissioning, including energization procedures, LOTO, approach boundaries, PPE verification, and pre-energization walkdowns. Coordinate safety briefings and documentation with commissioning crews, site operations, safety teams, and owner representatives.
Requirements
Requires 10+ years of electrical safety, commissioning, or field engineering experience on medium-voltage power systems, with expert NFPA 70E knowledge and experience interpreting IEEE 1584 arc-flash studies. Candidates must have managed concurrent energized and de-energized zones and developed energization procedures for multi-source critical power systems; NETA Level IV and OSHA 30 are preferred.
Skills
- Electrical Safety
- Medium-Voltage Switchgear Commissioning
- Energization Procedures
- Lockout/Tagout (LOTO)
- Approach Boundary Management
- Arc-Flash PPE Assignment
- IEEE 1584 Arc-Flash Study Interpretation
- NFPA 70E Compliance
- Safety Plan Development
- Pre-Energization Walkdowns
- Safety Briefings
- Staged Commissioning
- Critical Power Systems
- Multi-Source Power Systems
- Site Stakeholder Coordination
- Commissioning Documentation
Visa sponsorship
Not detected in the job text
Categories
- Engineering
- Security & Safety
- Energy
- Management & Leadership
Keywords
- NFPA 70E
- NFPA 70
- NFPA 110
- NFPA 111
- IEEE 1584
- Medium-Voltage Switchgear
- Critical Power Systems
- Energization Safety
- Lockout/Tagout (LOTO)
- Approach Boundaries
- Arc-Flash PPE
- Incident Energy Calculations
- Energized Work Permits
- Electrical Safety Plans
- Multi-Source Power
- Generators
- Uninterruptible Power Supplies (UPS)
- Factory Acceptance Testing (FAT)
- Site Acceptance Testing (SAT)
- Witness Testing
- Staged Commissioning
- Cutover
- SEL
- Woodward
- NETA Level IV
- OSHA 30
- Qualified Electrical Workers
- Safety Walkdowns
- Mission-Critical Infrastructure